Product Details:
Payment & Shipping Terms:
|
| Product Name: | Thru Coatings Ultrasonic Thickness Gauge/ Echo To Echo UT Gage/ NDT Meter/NDE Tester RTG700 | Display: | Color OLED |
|---|---|---|---|
| A-Scan Snapshot: | Yes | Gain: | Low, Medium, High |
| Measuring Range: | 0.60mm To 508mm | Measuring Resolution: | Selectable 0.01mm, 0.1mm |
Features:
Color 320x240 Pixels Display
A-Scan Snapshot
Echo-Echo Mode(Thru Paint & Coatings)
Stores 100,000 Readings
Gain: Low, Medium or High for varying test conditions
Technical Specifications
|
Feature
|
RTG700 | RTG700D | RTG700DL | Data Logger Option |
|
Color Display
|
Yes |
Yes |
Yes |
|
|
A-Scan Snapshot
|
Yes |
Yes |
Yes |
|
|
Gain: Low, Medium, High
|
Yes |
Yes |
Yes |
|
|
Min/Max Capture
|
Yes |
Yes |
Yes |
|
|
DIFF/RR%
|
Yes |
Yes |
Yes |
|
|
Thru-paint
|
X |
Yes |
Yes |
|
|
Data Logger
|
X | X |
Yes |
Yes |
|
DataView Software
|
X | X |
Yes |
Yes |
|
Instrument Specifications
|
|
|
Display Type
|
2.4" color OLED, 320 X 240 pixels, contrast 10,000:1 |
|
Operating Principle
|
Pulse echo with dual element transducers |
| Measuring Range | 0.60mm to 508mm(0.025" to 20.00"), depending on material, probe and surface condition |
|
Measuring Resolution
|
Selectable 0.01mm, 0.1mm(selectable 0.001", 0.01") |
|
Units
|
Inch or Millimeter |
|
Gain
|
Low, Medium or High for varying test conditions |
|
Display Mode
|
Normal, Minimum / Maximum capture, DIFF/RR% |
|
V-Path Correction
|
Automatic |
|
Update Rate
|
Selectable 4Hz, 8Hz, 16Hz |
|
Material Velocity Range
|
500 to 9999m/s (0.0197 to 0.3937in/us) |
|
Languages
|
Selectable Chinese, English, Japanese |
|
Alarm Settings
|
Minimum and Maximum alarms. Range of 0.25 mm to 508 mm (0.010" to 20.00"). Dynamic waveform color change on alarm |
|
Power Requirements
|
2 AA size batteries |
|
Operating Time
|
Approximately 40 hours |
|
Instrument Shut-off
|
Selectable ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity |
|
Operating Temperature
|
-10°C to +50°C (+10°F to +120°F) |
|
Size
|
153mm X 76mm X 37mm(H X W X D) |
|
Weight
|
280g including batteries |
|
Data Logger Option Features
|
|
|
Capacity
|
400 files, 100,000 readings |
|
File Structure
|
Grid file |
|
Rows X Columns
|
21 X 12 |
|
Communication Port
|
USB 2.0 (Full Speed ) port |
|
Software
|
DataView PC software |
Standard accessories
|
Thickness Gauge
|
1 |
|
Probe
|
1 |
|
Alkaline Battery
|
2 |
|
Couplant
|
1 |
|
Carrying Case
|
1 |
|
Operation Manual
|
1 |
|
USB Cable
|
1(Only RTG700DL) |
|
Software CD
|
1(Only RTG700DL) |
Optional accessories
|
High-temperature Probe
|
Cast Iron Probe |
|
Small Probe
|
Mini Probe |
|
Probe Cable
|
Stepped Calibration Block |
|
Rubber Sheath
|
Storage Option(Only RTG700DL) |